<img alt="" src="https://secure.agile-company-365.com/781893.png" style="display:none;">
emitters-hero

Trajan CB Emitters

 

Trajan CB Emitters. No clogs. Just uptime.

Introducing the Trajan CB Emitter

To address our customer’s challenges, we developed the Trajan CB Emitter. Unlike traditional pulled emitters with a tapered internal diameter, Trajan CB Emitters are engineered with a constant bore design that maintains a uniform ID right to the tip - reducing clog risk, minimizing downtime and reruns, and keeping workflows uninterrupted.

Consistent performance for demanding workflows 

Trajan CB Emitters don’t just reduce clogging – they’re precision-engineered in-house to deliver the sensitivity, accuracy and consistency essential for high-performance proteomics. Every detail is designed to keep workflows moving and results reliable.

best-compatible-nanospray-emitters-high-throughput-proteomics
Keep workflows moving run after run with Trajan CB Emitters for LC-MS

Consistent performance for demanding workflows

Trajan CB Emitters don’t just reduce clogging – they’re precision-engineered in-house to deliver the sensitivity, accuracy and consistency essential for high-performance proteomics. Every detail is designed to keep workflows moving and results reliable.

Coating options

Choosing the Trajan CB Emitter with the right coating ensures optimal spray stability and compatibility with your LC-MS setup. Here’s what each option offers:
Uncoated

Trajan CB Emitter, uncoated (UC) graphic

 Trajan CB Emitter, uncoated (UC) photo


For source configurations where voltage is applied to the liquid junction. This is the simplest configuration, suitable for standard workflows where electrical contact at the junction is sufficient.

Request quote

Gold tip coated

Trajan CB Emitter, gold tip coated (GTC) graphic

 Trajan CB Emitter, gold tip coated (GTC) photo

For source configurations where voltage is applied to the emitter body, this option enhances spray stability and improves efficiency for non FAIMS applications.

Request quote

Gold distal coated

Trajan CB Emitter, gold distal coated (GDC) graphic


Trajan CB Emitter, gold distal coated (GDC) photo

Features a non-conductive tip that eliminates arcing in FAIMS systems. This design allows closer positioning to the FAIMS interface for a more stable spray and improved ion transmission.

Request quote

Emitter - Fusion3-Test

Constant bore explained

A constant bore emitter maintains a uniform internal diameter right to the tip, eliminating abrupt constrictions that can disrupt fluid dynamics. This streamlined design promotes smooth, laminar flow, minimizes turbulence, and reduces sites for particle buildup — significantly lowering the risk of clogging.

The outcome is fewer interruptions, fewer reruns, and consistently higher throughput for demanding workflows.

Constant bore explained

A constant bore emitter maintains a uniform internal diameter right to the tip, eliminating abrupt constrictions that can disrupt fluid dynamics. This streamlined design promotes smooth, laminar flow, minimizes turbulence, and reduces sites for particle buildup — significantly lowering the risk of clogging.

The outcome is fewer interruptions, fewer reruns, and consistently higher throughput for demanding workflows.

 


“Because these emitters have a completely straight internal bore with no taper, they very rarely clog if you’re careful with them. In fact, it’s almost impossible to block them.”

 

 
Dr. Matt Padula Director, Proteomics and Metabolomics Platform, University of Technology Sydney, Australia

 


Dr. Matt Padula
Director, Proteomics and Metabolomics Platform, University of Technology Sydney, Australia

“In the laboratory, our core objective is to deliver high-quality results to all of our collaborators on time. Trajan CB Emitters have demonstrated exceptional robustness in our non-integrated emitter column configurations, often lasting through hundreds of injections.”


Proteomics Lab Manager
Metabolomics and Proteomics Facility

"We have performed hundreds of runs using Trajan CB Emitters, and the spray quality has proven to be very robust and reproducible. When using other emitters, we found that despite sample cleaning processes, certain samples or matrices interfered with the spray - and in extreme cases, caused blockages. These issues result in significant LC-MS downtime and delays in project deliverables."

 

Dr Gagan Deep Jhingan, VProteomics, India

  

Dr. Gagan Deep Jhingan
VProteomics, India

“We consistently observe excellent spray stability and minimal emitter-to-emitter variability, which ensures intra-batch consistency, reduces the need for reacquisitions, and safeguards data integrity. These qualities make Trajan CB Emitters a critical component in maintaining reliability and efficiency across many of our workflows.”


Proteomics Lab Manager
Metabolomics and Proteomics Facility


Explore the key benefits that matter most

Keep your runs moving - don't lose samples

Keep your runs moving

Reduce downtime, reruns and rework with a constant bore, clog-resistant design.

Maximize sensitivity and proteome coverage in Nano-ESI-LCMS

Maximize sensitivity and proteome coverage

Thanks to precision-cleaved, zero dead volume (ZDV)-compatible ends and a tip geometry optimized for superior spray efficiency.

Ensure accuracy and precision for reliable ESI spray performance

Ensure accuracy and precision

With an optimized tip geometry that delivers stable, efficient spray performance.

Deliver consistent performance between tapered nanospray constant bore emitters

Deliver consistent performance

Tight tolerances minimize variability between emitters, reducing the need for reruns after emitter replacements.

Run any sample due to the chemically inert fused silica which is drawn in-house

Run any sample

With chemically inert fused silica that supports even phosphorylated proteins.

Precision engineered for consistent analytical performance for proteomics

Commitment to quality

Trajan CB Emitters undergo comprehensive quality testing to ensure every emitter delivers a high level of analytical performance.

Every single emitter passes rigorous manufacturing control processes and high-resolution microscopic inspection, with each pack supplied with a Certificate of Conformance. 

Make the right choice

Find the right fit for your LC-MS setup with our Emitter Selection Tool.

Quickly filter to identify the recommended emitters for your source configuration, sample types and workflow.

Loading products...


Download resource documents

Ready to start your clog-free journey?

Request a free sample today. Fill out your details and your closest Trajan expert will be in touch.


Learn more

Explore the key benefits that matter most, learn about key technical features, download resources and browse options in the selection tool.

© 2026 Trajan Scientific and Medical. Trajan Scientific Australia Pty Ltd.